In the continuing fight against terrorism, the WG 6000 is the answer to one of the terrorists' greatest threats - concealed explosives. The WG6000 is an integrated system solution addressing the need for detection of large vehicle-bombs with a high vehicle through-put.
WG 6000 combines an automated touch-less vehicle sampling system with patented GC/IMS chemical detection. This system is fully automated for continuous operation and is driven by an intuitive icon-based interface that is both user-friendly and highly reliable. The WG 6000 can be adapted to suit site-specific architectural and various threat detection requirements.
The WG 6000 can be effective in a wide-range of applications:
- Government facilities;
- Military installations;
- Transportation terminals;
- Industrial sites;
- Security establishments;
- Religious sites;
- Embassies;
- Office towers;
- Nuclear facilities.
Specifications
Vehicle Size Standard maximum dimensions:
- 2.20 m wide x 2.25 m high x 8 m long;
- 7.21 ft wide x 7.37 ft high x 26.2 ft long.
Larger sizes available for applications with larger vehicle and/or cargo containers.
Throughput Time: Typically less than one minute (dependent on operational configuration).
Explosive Detection Capability: TNT, NG, AN, EGDN, o-MNT, p-MNT, DMNB, Dynamite, smokeless powder & other commercially available explosives.
Analytical Unit Sensitivity
- Vapours: parts per trillion;
- Particulates: nanograms to picograms.
Components
- GC/IMS chemical detection units;
- Air compressor;
- Vacuum blowers;
- Air receivers (2);
- Vehicle scanning facility;
- Digital PTZ camera(s);
- Recording system;
- Electrical and control panel;
- System integration computer, industrial grade;
- Electronics rack.
Operator Features
- Audible and visual alarm annunciation;
- Fully Automatic Operation;
- Graphical interface with animation of system operation;
- Integrated operation, scanning system, doors, optional sub-systems;
- Fault condition alarms for all equipment.
Power Requirements Standard equipment:
- 72 kVA, 3 phase, 575 VAC, 60 Hz (includes 2 kVA conditioned power);
- 10 kVA, 1 phase, 115 VAC, 60 Hz conditioned, UPS recommended;
- Optional voltage/frequency powering available;
- 400/230 VAC, 50 Hz;
- 208/115 VAC, 60 Hz.
Space Requirements
Operator room, local or remote, 9 m2 (100ft2);
Equipment room, 16 m2 (172ft2), 3.6 m ceiling clearance adjacent to scanning area;
Vehicle scanning area, 5 m wide, 11.5 m long, 4.5 m ceiling clearance;
(16.4 ft wide, 37.7 ft long, 14.8 ft ceiling clearance).
Environmental Requirements
Operator room, typical indoor office environment;
Equipment room, controlled, 25°C ± 5°;
Vehicle scanning area, 5°C to 40°C.
System Optional Components and Design Services
- Under-vehicle scanning;
- Remote operation;
- Integrated weigh scale;
- Architectural/system design support;
- Vehicle containment options;
- Blast containment options;
- GS/IMS/CL Detector.